MODEL X96S
Process Computer:
Microprocessor-based unit with a liquid crystal display, push-button interface,
HART
Communications, process control outputs, process condition inputs, serial
communications.
Chassis:
19” rack mount, surface mount, or panel mount.
Enclosure:
Standard NEMA-4
Stainless Steel NEMA-4X
Explosion Proof
Electrical:
Power inputs: 90-240VAC +/-15%, 50-60 Hz; 24VDC +/-15%
Environmental:
Ambient temperature range: 0 degrees to 140 degrees F (18 degrees to 60 degrees
C)
Humidity: 90% non-condensing
Electronics:
Processor: Embedded 80x86 compatible processor
Memory: flash, static RAM, battery backup RAM
A/D Converters: 16-bit, dual slope, auto-zeroing
Display: graphic LCD, fluorescent back-lit
Inputs:
(Optional)
Tachometer: 0-10VDC, 4-20mA, or pulse rate TTL load
Detector: 0.42-2.4VDC or pulse TTL
Temperature Compensation: 100 ohm Pt, 120 ohm Ni, or 4-20mA
(mass flow or density)
Outputs:
Three 4-20mA; one assigned to each channel
Four single set-point SPDT relays: 3 amp at 28VDC or 240VAC
Remote totalizer pulse: 20 msec pulse, open collector 50mA at 24VDC
Display Units:
(Engineering units per gauge)
Level: in, ft, mm, cm, or m
Density: % solids, SpG, Baume H, Baume L, or API, Brix, Ball or Twadell
Mass Flow: lb/min, Kg/min, mT/min, mT/hr, sT/min, sT/hr, lT/min, or lT/hr
Weight: lb/min, kg/min, mT/hr, sT/hr, kg/hr, or kg/hr, or oz/min
Computer Interface:
HART
Communications