Relay Failure
This failure will probably become apparent during a System Verify (Manual or
Automatic). If a failure occurs with an Alarm Relay, go to the Administrative Options –
Configure – Configure Relay Output Assignments, and re-assign the failed relay to
another working relay. The Alarm Relays are located in the Monitor Panel and will
require repair/replacement of the printed circuit board inside the unit.
If the relay failure is a Verification Notification relay, Speed Notification relay, or a Gate
Control relay, these are located on the frame in the Remote I/O Enclosure. See the
section on Remote I/O Failure for help here.