Ronan X55-600 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Équipement Ronan X55-600 Series. Ronan X55-600 Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - I TO P TRANSDUCERS

InstructionsandOperating ManualSERIES X55-600I TO P TRANSDUCERS

Page 2 - TABLE OF CONTENTS

ORDERING INFORMATIONX55-600 - GP - ( ) - SMOUTLINE DRAWINGGENERAL PURPOSE SURFACEMOUNT TRANSDUCER8Surface MountOutput Range1 = 3-15 psig2 = 3-27 ps

Page 3 - 1.0 GENERAL DESCRIPTION

ORDERING INFORMATIONX55-600 - GP - ( ) - MOUTLINE DRAWINGGENERAL PURPOSEMANIFOLD MOUNT TRANSDUCERManifold MountOutput Range1 = 3-15 psig2 = 3-27 ps

Page 4 - 3.0 INSTALLATION

ORDERING INFORMATIONX55-600 - EX - ( ) - SMSurface MountOutput Range1 = 3-15 psig2 = 3-27 psig3 = 6-30 psigExplosion ProofOUTLINE DRAWINGEXPLOSION

Page 5 - 4.0 OPERATION

ORDERING INFORMATIONX55-600 - N4 - ( ) - DINDIN Rail MountOutput Range1 = 3-15 psig2 = 3-27 psig3 = 6-30 psigNEMA 4Weather Proof1/2 NPTOUTLINE DRAW

Page 6 - 6.0 TROUBLESHOOTING

OUTLINE DRAWINGNEMA 4 SURFACE MOUNTTRANSDUCER12ORDERING INFORMATIONX55-600 - N4 - ( ) - SMSurface MountOutput Range1 = 3-15 psig2 = 3-27 psig3 = 6-

Page 7 - FOR LOSS OF POWER

!ORDERING INFORMATIONX55-600 - SMC - ( ) 4 point Capacity8 point Capacity10 Point CapacityOUTLINE DRAWINGSURFACE MOUNT MANIFOLD136.955(176.66MM)AB!

Page 8 - Printed in the U.S.A

ORDERING INFORMATIONX55-600 - GP - ( ) - DINDIN Rail MountOutput Range1 = 3-15 psig2 = 3-27 psig3 = 6-30 psigGeneral PurposeOUTLINE DRAWINGGENERAL

Page 9 - 8.0 ORDERING INFORMATION

ORDERING INFORMATIONX55-600 - RM - 8OUTLINE DRAWINGRACK MOUNT-8MANIFOLD157.065(179.45MM)3.000(76.20MM)!!0.250(06.35MM).234(5.94MM)!!!!!!!18.312(465.12

Page 10 - (4) 8-32 cap screws

ORDERING INFORMATIONFilter Regulator = X55 - 77 - 4Output Gauge = X55 - 0 - 30Input Gauge = X55 - 0 - 60(Input Gauge not shown)OUTLINE DRAWINGPREREGUL

Page 11

OUTLINE DRAWING2" DIAMETER PIPE MOUNT BRACKET17

Page 12

TABLE OF CONTENTS1.0 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12.0 Specific

Page 13

OUTLINE DRAWING2" DIAMETER PIPE MOUNT BRACKET18

Page 14

19X55-600-UMBX55-600-UMB-SS (STAINLESS STEEL)MOUNTING BRACKET

Page 15 - (176.66MM)

InstructionsandOperating ManualSERIES X55-600I TO P TRANSDUCERSAddendumEffective March 2004INSTALLATION IN HAZARDOUS ENVIRONMENTSThe X55 I/P transduce

Page 16

Category and Code Marking for Model X55-600-EX:Explosion Proof:CSA or Factory Mutual Class I, II, III; Division 1, Groups B, C, D, E, F, GExplosion Pr

Page 17

RONAN ENGINEERING RONAN ENGINEERING RONAN ENGINEERINGCOMPANY LIMITED U.K. LIMITEDP.O. Box 1275 1 Tilley Road 32 Bermondsey Road21200 Oxnard Street Cro

Page 18

input signal, i.e., when the input signalincreases toward full scale, the output pres-sure decreases toward the zero value.TheSPLIT/FULL switch, when

Page 19 - OUTLINE DRAWING

Temperature Drift: 0.01% of span per °Ffrom 30 to 150°F (.025% below 30°F).Feed Flow (Output) Capacity: 3.0 SCFM at20 psi supply, 10.5 SCFM at 100 ps

Page 20

3.3 Manifold Mounted ModelsThe manifold mounted transducersshare a single 3/8-18 NPT female inletwhile having individual 1/4-18 NPTfemale outlet fitti

Page 21 - MOUNTING BRACKET

5.0 CALIBRATIONShould calibration be required, use the fol-lowing procedure. NOTE: if one of the frontpanel switches is changed to a new position,the

Page 22

require the removal of the four 7/64Allen head screws holding the blackcover to the grey metal base.7. Using Figure 1, locate the 0 mA “AirPin.”8. Rea

Page 23

eventually cause corrosion damage tothe I/P.Coalescing filters is an inexpensive way tohelp prevent I/P malfunctions or failures.These filters remove

Page 24

MANIFOLD CHASSISMODEL DESCRIPTIONX55-600-SMC-4 Surface Mount Manifold Chassis with manual shutoffX55-600-SMC-8 Surface Mount Manifold Chassis with man

Commentaires sur ces manuels

Pas de commentaire